| Care
and Tips for Motorola Rechargeable Batteries |
1) Charge
your new battery overnight before using it.
This is referred to as
INITIALIZING and will
enable you to obtain maximum battery capacity.
a. Nickel Cadmium or Nickel Metal Hydride:
14-16 hours
b. Lithium Ion/Polymer:
1 or 2 additional hours after the charger light turns green
2)
New Motorola IMPRES batteries,
when inserted into a Motorola impres charger, will indicate
a calibration cycle by displaying a steady yellow indication on
the charge status indicator. Allow this calibration process
to complete by not removing the battery from the charger
until it has completely charged and displays a steady green
indication.
3)
In order to minimize capacity loss and cycle life reduction, new
NON INITIALIZED batteries must be stored in well ventilated, cool
and dry locations. Batteries stored in these conditions
may be stored:
a. Nickel Cadmium up to 2
years
b. Nickel Metal Hydride up to 18 months
c. Lithium Ion/Polymer up to 18 months
4)
If used batteries are to be removed from service
for extended periods (greater than 30 days) they should
be discharged to about 50% of their capacity before storage
in a cool, dry location.
5)
Batteries that have been in storage for more than two months
should be fully discharged and recharged.
a. Nickel Cadmium or Nickel
Metal Hydride: 14-16 hours
b. Lithium Ion/Polymer: 1 to 2 additional hours after the charger
light turns green
6)
When using a Motorola rapid charger, leave the battery in
the charger for an additional 1 to 2 hours after the steady green
light appears (applies to non-IMPRES
batteries only).
7)
Do not leave your radio and fully-charged
battery in the charger when not charging. Continuous charging
will shorten battery life (do not use charger as a radio stand).
8)
Only charge a battery when it needs it. If it is
not fully discharged, do not recharge it. We suggest that you carry
a spare. This is the cost effective solution for users requiring
longer operating time.
9)
Do not return fully charged non-impres batteries to the
charger for an extra boost. This action will significantly
reduce cycle life. Repeated short cycle charging of non-IMPRES batteries
will shorten battery life (Do not use charger as a radio stand for
non-IMPRES batteries).
10)
Stabilize batteries to room temperature (72°F) before
charging. Charging below 40°F and above 104°F will
decrease life cycle.
|